CVE-2026-7480: An Incorrect Permission Assignment for Critical Resource vulnerability in ASUS System Control Interface allows a local user to elevate privileges to SYSTEM and execute arbitrary code via a crafted RPC call that bypass the validation mechanism
An Incorrect Permission Assignment for Critical Resource vulnerability in ASUS System Control Interface allows a local user to elevate privileges to SYSTEM and execute arbitrary code via a crafted RPC call that bypass the validation mechanism. Refer to the 'Security Update for ASUS System Control Interface' section on the ASUS Security Advisory for more information.
HarborGuard Analysis
HarborGuard analysisSynopsis
Incorrect permission assignment on a critical resource in ASUS System Control Interface lets a local user elevate to SYSTEM by issuing a crafted RPC call that bypasses the validation mechanism. The attacker needs an existing low-privileged account on the host and no user interaction, and successful exploitation yields full SYSTEM-level arbitrary code execution. No fix is published yet, and HarborGuard tracks the advisory for patch availability.
HarborGuard Coverage
Detection is available across every HarborGuard environment: the CVE is ingested from upstream feeds within minutes of publication and matched against ASUS System Control Interface components found in customer registries, pipelines, and custom-built images.
AvailableTriage is available with the CVSS v4 base score of 7.3 (HIGH) weighted against each customer's compliance policy, then routed to the appropriate inbox inside the customer's org so the right team owns the finding.
AvailableNo upstream fix is currently published. HarborGuard re-checks the ASUS advisory each ingest cycle and will make a patched-image rebuild available the moment the vendor ships a fixed version; auto-remediation customers will then receive a rebuild, regression-test run, and PR opened against affected workloads.
Pending upstreamExploit Conditions
- Network reachabilityNot required
AV:L means the attacker needs an existing shell or process on the host; there is no network-facing entry point.
- AuthenticationRequired
PR:L means any low-privileged local account on the system is sufficient to launch the RPC call.
- Victim interactionNot required
UI:N means no user has to click, open, or approve anything for the exploit to succeed.
- Attack complexityDetail
AC:H indicates the exploit depends on environmental factors such as race timing or specific system state to reliably bypass the validation mechanism.
Blast Radius
- Executes arbitrary code as SYSTEM, giving the attacker full control over the Windows host.
- Reads any file or process memory on the system, including credentials and protected configuration.
- Modifies or replaces operating-system binaries, services, and persistence mechanisms.
- Disrupts or disables security tooling and other services running on the host.
How HarborGuard Handles This
Available on HarborGuard: continuous monitoring of the ASUS advisory for a published fix, with the patched-image rebuild made available automatically the moment upstream ships. In the meantime, the platform surfaces compensating-control guidance for affected workloads, including restricting local logon rights on hosts running ASUS System Control Interface, isolating affected endpoints with host-level network policy, and gating the service behind feature flags where the component is not strictly required. For environments with auto-remediation enabled, the rebuild, regression run, and PR against affected workloads will trigger as soon as a fixed version is published.
Metrics
- CVSS v4.0
- 7.3
- Severity
- HIGH
- Fixed in
- —
- Affected Products
- 2
- ASUS / ASUS System Control Interface3.1.59.0 and earlier
- ASUS / ASUS System Control Interface3.2.60.0 and earlier
CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N