HarborGuardharborguardDatabase
Back to search
CRITICALCVE-2026-54257Published Modified CNA GitHub_M

CVE-2026-54257: Electron: Buffer performs incorrect byte length calculations resulting in heap buffer under/overflow

Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. From 42.3.1 until 42.3.3, Buffer performs incorrect byte length calculations resulting in heap buffer under/overflow. Most apps will crash and some may perform incorrect buffer allocations in the Node.js Buffer API resulting in unexpected truncation or allocation. This vulnerability is fixed in 42.3.3.

Metrics

CVSS v4.0
9.3
Severity
CRITICAL
Fixed in
Affected Products
1

Get notified

Email me when this CVE is updated: new fix versions, severity changes, or any record change.

HarborGuard Analysis

Synopsis

A heap buffer under/overflow vulnerability affects the Electron framework, specifically versions 42.3.1 through 42.3.3, due to incorrect byte length calculations in the Node.js Buffer API. The flaw is reachable over the network with no authentication required and no user interaction needed, making it exploitable against any Electron-based desktop application that processes external input. Successful exploitation causes the affected application to crash and may allow incorrect buffer allocations leading to memory corruption, data truncation, or arbitrary code execution. No fix version has been published upstream yet; HarborGuard tracks this advisory and will make a patched-image rebuild available the moment an upstream fix is released.

HarborGuard Coverage

Detection

Detection of CVE-2026-54257 is available across every HarborGuard environment - the CVE is ingested from upstream feeds (including the GitHub Advisory Database) within minutes of publication and matched against all customer images, including custom-built images that bundle Electron 42.3.1 or 42.3.2. Scanning covers both registry images and images evaluated at CI/CD pipeline stages before deployment.

Available
Triage

Triage is available with the full CVSS v4.0 score of 9.3 (Critical) applied automatically, weighted further against each customer environment's compliance policy to prioritize findings by business context. Routed findings are delivered to the appropriate team inbox within each customer organization based on image ownership and policy configuration.

Available
Patch

No upstream fix version has been published for this CVE at this time; HarborGuard re-evaluates the advisory on every ingest cycle and will make a patched-image rebuild available automatically the moment Electron ships a remediated release. For customers with auto-remediation enabled, the rebuild, regression test run, and PR against affected workloads will be triggered without manual intervention once a fix version is confirmed.

Pending upstream

Exploit Conditions

  • Network reachabilityRequired

    The vulnerable code path is exposed over the network, meaning an attacker can send crafted input to the application from a remote host without requiring any foothold on the target system.

  • AuthenticationNot required

    No credentials or prior authentication are needed to trigger the incorrect byte length calculation; the flaw can be reached by any unauthenticated party that can send input to the application.

  • Victim interactionNot required

    Exploitation does not depend on a user clicking a link or performing any action; the attacker can trigger the vulnerability entirely without victim participation.

  • Attack complexityDetail

    Attack complexity is low, meaning the exploit is reliable and requires no special environmental conditions, race conditions, or memory layout prerequisites to trigger the buffer miscalculation.

Blast Radius

  • A successful attacker causes the Electron application to crash, making it unavailable to the end user (high availability impact against the vulnerable component).
  • Incorrect buffer allocations allow the attacker to read memory contents outside intended boundaries, exposing in-memory data such as session tokens, credentials, or application state (high confidentiality impact).
  • The buffer under/overflow enables writes to adjacent heap memory, allowing an attacker to corrupt application data or manipulate program logic in ways that alter persisted or in-flight data (high integrity impact).
  • In the worst case, controlled heap corruption provides a path to arbitrary code execution within the Electron renderer or main process, giving the attacker full control of the application context.

How HarborGuard Handles This

Available on HarborGuard: detection of this Critical-severity CVE (CVSS v4.0 9.3) is active across all customer environments scanning images that include Electron 42.3.1 or 42.3.2, with no configuration required. Because no upstream fix version exists at this time, HarborGuard re-checks the advisory on every ingest cycle and will make a patched-image rebuild available automatically as soon as Electron publishes a remediated release. For customers with auto-remediation enabled, the rebuild, regression test run, and PR against affected workloads will be triggered without manual action the moment the fix lands. In the interim, compensating controls worth evaluating include network-policy isolation to restrict inbound input surface for affected Electron applications, egress filtering to limit what the process can reach if heap corruption is achieved, and where feasible, feature-flag gating of functionality that exercises the Node.js Buffer API with externally supplied data. HarborGuard will surface a patch-available notification to affected environments the moment upstream confirms a fix.

See how HarborGuard automates this
Affected packages
  • electron / electron
    >= 42.3.1, < 42.3.3
CVSS Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N