HarborGuardharborguardDatabase
Back to search
HIGHCVE-2026-46748Published Modified CNA siemens

CVE-2026-46748: A vulnerability has been identified in SINEC INS (All versions < V1

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected system includes a binary that is configured with the cap_dac_override capability. This capability allows the process to bypass file system permission checks, resulting in unrestricted file system access. This could allow a local attacker to escalate privileges leading to arbitrary file modification and gaining root privileges on the system.

Metrics

CVSS v4.0
8.7
Severity
HIGH
Fixed in
V1.0 SP2 Update 6
Affected Products
1

Get notified

Email me when this CVE is updated: new fix versions, severity changes, or any record change.

HarborGuard Analysis

Synopsis

A privilege escalation vulnerability exists in Siemens SINEC INS affecting all versions before V1.0 SP2 Update 6. A local attacker with a low-privilege account can exploit a misconfigured binary that holds the cap_dac_override Linux capability, which allows the process to bypass all file system permission checks. Successful exploitation gives the attacker full read, write, and execute access across the file system, enabling them to gain root privileges on the affected host. A patched-image rebuild at V1.0 SP2 Update 6 is available on HarborGuard for environments running an affected version.

HarborGuard Coverage

Detection

Detection of CVE-2026-46748 is available across every HarborGuard environment; the CVE is matched against customer images within minutes of publication against upstream NVD, Siemens ProductCERT, and supplementary advisory feeds, covering both vendor-supplied and custom-built images that include the affected SINEC INS binary. Any image layer containing a SINEC INS version below V1.0 SP2 Update 6 is flagged automatically across connected registries and CI/CD pipeline stages.

Available
Triage

HarborGuard scores this finding at CVSS v4.0 8.7 (HIGH) and weights it against each customer organization's configured compliance policy, elevating or suppressing alert priority accordingly. Triage findings are routed to the appropriate team inbox within each customer org based on image ownership and policy assignment.

Available
Patch

A patched-image rebuild at V1.0 SP2 Update 6 is available on HarborGuard for any environment scanning an affected image. For customers who opt into auto-remediation, HarborGuard performs the rebuild, runs a regression test suite against the updated image, and opens a pull request against affected workloads automatically.

Available

Exploit Conditions

  • Network reachabilityNot required

    The attacker needs an existing shell or process on the host; no network access to the service is required to trigger the vulnerability.

  • AuthenticationRequired

    Any low-privilege local account is sufficient; no administrative credentials are needed to invoke the misconfigured binary.

  • Victim interactionNot required

    No user interaction is required; the attacker can exploit the misconfigured capability entirely without involving another user.

  • Attack complexityDetail

    The exploit is reliable and condition-free; no race conditions, special memory layout, or environmental prerequisites are required beyond local access.

Blast Radius

  • Attacker reads arbitrary files across the entire file system, including credential stores, private keys, and application secrets.
  • Attacker writes or overwrites arbitrary files, including system binaries and configuration files.
  • Attacker escalates to root privileges, gaining full control of the operating system and all processes running on the host.
  • All three integrity, confidentiality, and availability dimensions of the local system are fully compromised once root is obtained.

How HarborGuard Handles This

Available on HarborGuard: detection for CVE-2026-46748 activates automatically against any scanned image containing SINEC INS below V1.0 SP2 Update 6. Because this is rated HIGH at CVSS v4.0 8.7, it is prioritized for fast triage routing within each customer org's policy configuration. A patched-image rebuild at V1.0 SP2 Update 6 is available; for customers with auto-remediation enabled, HarborGuard initiates the rebuild, executes regression tests, and opens a PR against affected workloads, with a median time from CVE publication to merged patch PR of around 90 minutes for high-severity issues in auto-remediation-enabled environments. Where compliance policy requires manual approval, the rebuild artifact and test results are staged and held for engineer review. Customers who cannot immediately apply the patch should consider restricting local shell access to the affected host, applying file integrity monitoring to sensitive paths, and auditing which service accounts have the ability to invoke the affected binary.

See how HarborGuard automates this

Fix available

V1.0 SP2 Update 6
Affected packages
  • Siemens / SINEC INS
    < V1.0 SP2 Update 6 (from 0)
CVSS Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N