HarborGuard / CVE
Back to search
CRITICALCVE-2026-39462Published Modified CNA icscert

CVE-2026-39462: SenseLive X3050 Insufficiently Protected Credentials

A vulnerability exists in SenseLive X3050’s web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly.

Metrics

CVSS v4.0
9.3
Severity
CRITICAL
Fixed in
Affected Products
1
Affected packages
  • SenseLive / X3050
    V1.523
CVSS Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N