HIGHCVE-2026-25656Published Modified CNA siemens
CVE-2026-25656: A vulnerability has been identified in SINEC NMS (All versions < V4
A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3), User Management Component (UMC) (All versions < V2.15.2.1). The affected application permits improper modification of a configuration file by a low-privileged user. This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with SYSTEM privileges.(ZDI-CAN-28108)
Metrics
- CVSS v4.0
- 8.5
- Severity
- HIGH
- Fixed in
- V2.15.2.1
- Affected Products
- 2
Fix available
V2.15.2.1V4.0 SP3
Affected packages
- Siemens / SINEC NMS< V4.0 SP3 (from 0)
- Siemens / User Management Component (UMC)< V2.15.2.1 (from 0)
CVSS Vector
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NReferences